Description
Shown in picture: Casablanca Twain Ceiling Fan
Model C25G624F in Bullion Black. The light fixture and Reclaimed Antique Outdoor Blades are included as shown. Light fixture uses 1-100Watt Halogen Bulb (bulbs included).**. Comes with 4 Speed rotary control with Light Dimmer. Dimmer requires 3rd hot wire for light dimming. Otherwise light comes on when fan is on.. Includes a built-in uplight for added ambiance.
Sometimes the Great Outdoors needs a really Great Ceiling Fan, so Casablanca designed the Twain. The large 60" blades of the Twain are driven by the Exclusive and Very Powerful Casablanca XTR200 motor which allows this fan to produce over 8,100 CFM of airflow. But not only does the Twain move more air than most other outdoor fans, it also includes a built-in uplight and downlight...which is rare for damp rated fans. Even more, the style of the fan is designed to replicate the cast iron lattice work of outdoor furniture found in 19th Century English parks. The Twain certainly not an ordinary ceiling fan.
Low, High or Vaulted Ceiling Installation Options
This ceiling fan can be installed on ceilings that are 8 or 9 feet high and can be angled up to 30 degrees without the need for any additional
mounting hardware, so what is in the box will be sufficient. If you have a high ceiling or vaulted ceiling that is angled more than 30 degrees (or both),
you may need a downrod or angled ceiling adapter in order to install your fan.
Minimum Ceiling Height Requirement: This fan requires a minimum ceiling height of at least 95.9" in order to meet building codes. If your ceiling is lower than 95.9" then you may need to add a flushmount adapter or close to ceiling dowrod if one is available for the fan (see below).
If you cannot find what you need to make this fan work in your room, please give us a call so we can check to see if there are any further alternatives.
How long of a downrod do I need?
Building codes require ceiling fans to be installed with the blades no lower than 7 feet from the floor in residential applications (industrial fans may require more distnace). The closer you are to the fan blades, the more cooling effect you will feel, so 7 feet is the optimal distance from the floor for most residential ceiling fans to get the most benefit.
The standard size downrod for the Casablanca Twain ceiling fan is 3", which puts the blades 11.9" from the ceiling. Here are the Minimum Ceiling Heights required for each downrod available for this fan. Each length will put the fan blades 7 feet from the floor, so if you want your fan blades higher than 7 feet, choose a shorter downrod to fit your needs.
- 6" Downrod for 8.24' ceilings (blades 14.9" from ceiling)
- 12" Downrod for 8.74' ceilings (blades 20.9" from ceiling)
- 18" Downrod for 9.24' ceilings (blades 26.9" from ceiling)
- 24" Downrod for 9.74' ceilings (blades 32.9" from ceiling)
- 30" Downrod for 10.24' ceilings (blades 38.9" from ceiling)
- 36" Downrod for 10.74' ceilings (blades 44.9" from ceiling)
- 48" Downrod for 11.74' ceilings (blades 56.9" from ceiling)
- 60" Downrod for 12.74' ceilings (blades 68.9" from ceiling)
X Hide this
About Angled Ceilings
This fan will hange from flat ceilings and ceilings angled up to 30 degrees using the hardware that comes in the box. If your ceiling is over 30 degrees, you can by an Angled Ceiling Adapter that will allow you to install the fan on a ceiling angled up to 45.
How to measure Rise:
Rise is the vertical distance your ceiling rises for every horizontal foot. Rise per foot is called Pitch. A roof with a 4/12 pitch rises 4 inches vertically for every 12 inches horizontal.
Our calculator uses roof pitch to calculate the angle of your ceiling. Since we already know the horizontal measurement is 12", we only need you to enter in the vertical rise to make the calculation.
To measure the rise of your ceiling: Hold a 12" ruler ruler horizontally (using a level) with one corner touching the ceiling. Then take measure the vertical distance from the other end of the ruler to the ceiling. This is the rise. Select your dimensions in the form above to calculate the angle of your ceiling. Most ceiling fans (except for hugger fans) can hang on ceilings angled up to 30 degrees without
the need for an angled ceiling adapter. 30 degrees is slightly less than a 7/12 pitch. Most angled ceiling adapters will allow your fan to hang up to 45 degress...which is a 12/12 pitch.
X Hide this
Casablanca Twain Dimensions
11.9"
16.7"
3"
16.2" Wide
5.6"
60"
14°
(Building codes require blades to be at least 7' from the floor)
Casablanca Twain Specifications
| Model Name | Casablanca Twain |
| Model Number | C25G624F |
| Motor Size | XTR200 30mm Motor |
| Quality Rating | 5 out of 5 (5 is best) |
| Blade Pitch | 14 degree blade pitch |
| Blade Span | 60" blade span |
| Blade Qty | 5 blades |
| RPMs | 157 RPMs |
| Speeds | 4 Speeds |
| Reverse Function | Yes |
| Indoor Rating | UL Listed for use indoors |
| Outdoor Rating |
UL Listed for outdoor DAMP locations in covered areas only. Cannot be directly exposed to rain.
|
| Includes Uplight | Yes |
| Uplight Specs | 6-25W Incandescent Bulbs (bulbs included). |
| Uplight watts | 150 Watts |
| Inludes Downlight | Yes |
| Downlight Type | Single Globe Fixtures |
| Downlight Description | Included Damp Rated Faux Alabaster Light Fixture for Twain |
| Downlight Bulbs | 1-100Watt Halogen Bulb (bulbs included). |
| Downlight Wattage | 100 Watts |
| Total Light Watts (including uplight) | 250
|
| ENERGY STAR Qualified | No |
| Style Group | Rustic-Log Home |
| Approx. Weight | 45lb |
| Warranty | Limited Lifetime Motor Warranty |
| Included Downrod(s) | 3" |
| Flushmount Capability | Cannot be flush mounted |
| Leadwire Length | Not Published |
Replacement Glass*
Please call to order replacement glass (if you have broken the glass on this fan).
FREE REPLACEMENT GLASS: If you purchased your fan from us in the past 5 years (on or after March 31st 2009) and have broken your glass, we may replace it FREE OF CHARGE based on our 5 Year FREE Replacement Parts Plan. Please call us so that we can verify that you made your purchase from us and that your glass is in fact broken (email us a picture of your fan and broken glass). Once verified, we will get you a replacement at no charge (just another advantage of buying your ceiling fans here at Hansen Wholesale). *All replacement glass sales are final, no refunds or exchages.
Casablanca Twain Ceiling Fan Comparison
How does the Casablanca Twain Compare to the Average Ceiling Fan?
Wind Speed: 4.73 MPH
(directly beneath the 60" blades)
Quality = 5 (average is 3)
With a Quality Rating of 5, this fan is among the finest quality ceiling fans made. It will run smooth and quiet without wobbling or making noise and you can let it run
24 hours a day for years on end without any worries of the motor burning out.
CFM Airflow = 8173 (average is 5755)
8173 CFM is a lot of airflow and is far above average, which is very good news if you want a ceiling fan
that can really cool you off. Fans like this will allow you to raise your thermostat by up to 10 degrees, which can save you as much as 40% on your cooling bills.
Some people find that fans like this pay for themselves during the first summer of operation.
Efficiency = 84 (average is about 76)
An Efficiency Rating of 84 is
pretty close to average.
Efficiency is defined by the EPA as the amount of airflow a fan produces (CFM) divided by the amount of
electricity (Watts) it uses on high speed without any lights on. Efficiency is less important than Airflow because more
CFMs allow you to raise your thermostat higher...which is where you will save the most energy. Efficiency becomes more important if
you expect to operate several ceiling fans at the same time. (see calculator below)
Watts = 97 (average is about 76)
97 Watts per hour is
higher than average, so this fan costs a little more to operate than other fans.
Use the calculator below to estimate just how much it will cost to operate this fan in "Your home".
Casablanca Twain Operational Cost Calculator
How to use our Ceiling Fan Cost Calculator
Basic Help: Our cost usage calculator shows you how much it will cost to operate the Casablanca Twain ceiling fan. By default, the calculator assumes that you will leave your fan running 24 hours a day for the entire year (which is not very likely to be accurate), so you will want to change the hours and days to be more in line with how often you think you will use the fan. The calculator also defaults to the average cost per kWh of electricity in the USA. You can change this to use the average cost of electricity in your state, although this may vary widely from city to city. For the most accurate calculation, manually enter the actual cost/kWh shown on your utility bill.
The wattage of the fan is already included (if it is known), but you can change it if you wish to see how the wattage affects the cost.
Fans with lights: Calculations are performed without lights by default. If you add a light fixture to the fan, you can add the wattage of the fixture to the wattage of the fan to perform calculations with the lights on. In some cases, when a light fixture of known wattage is included with the fan, the option to calculate with or without lights will show automatically. The light fixture on a ceiling fan almost always uses substantially more electricity than the fan motor, so it is very important to take that into account when comparing the overall operational cost between various ceiling fans
CFM -vs- Efficiency: CFM is KING! It is more important to buy a fan with higher CFMs than it is to buy a fan that uses less electricity. The highest wattage consumed by the most energy guzzling ceiling fan on our website is about 120 watts. So if you input 120 as the fan watts and run our calculator, you will see that it still costs less than 2 cents per hour to operate the most energy guzzling ceiling fan in most states.
You will get more savings with a higher CFM fan than a lower Wattage fan because if your fan moves more air
you will be able to raise your thermostat to a higher degree. Raising your thermostat by 10 degrees can save you up to 40% on your cooling bills. Choosing a less powerful fan because it uses less electricity can be the worst mistake you can make because it will not cool you off enough to allow you to raise your thermostat to a high enough level without becoming uncomfortable. This is why CFM is so much more important to consider than Wattage.
The average kWh by state used by our calculator is derived from information published by the
US Government Department of Energy as of May 2009.
Your actual cost may differ from this. Again, refer to your utility bill for your most recent kWh cost.
Performance Data
| RPMs |
CFMs |
Amps |
Watts |
EPA Efficiency (CFMs/Watt) |
High: 157
Med: NA
Low: NA
|
High: 8173
Med: NA
Low: NA
|
High: NA
Med: NA
Low: NA
|
High: 97
Med: NA
Low: NA
|
High: 84
Med: NA
Low: NA
|
"NA" means that the data was not available at the time this information was published or the manufacturer simply does not test for the data that is missing.